This structure contains many large study rooms that have the ability to be transformed into smaller study rooms through the use of foldable partitions. These partitions weigh approximately 9 psf of surface area and are present in five locations around the structure (with a total of seven partitions). The beams that support these partitions have been designed to resist the gravity load as well as any differential air pressure that may act on one side of the partition. The partition beams are designed for two cases. The first case is the in-use case where the partitions separate the room and act as a distributed load on the beam. The second case is when the partitions are in storage and act like a point load on the beam. These partitions carry a deflection limit of 2” per manufacturer warning. Calculations for these beams are included in Appendix J and details can be viewed on Drawing S10-1, S10-2, S10-3, S10-4, and S10-5.